Methicillin Resistance Test

Point-of-care molecular test · Test First, Treat Right

WeDetect Methicillin Resistance Test

Detects the mecA gene behind methicillin resistance in staphylococci, with a result in 40–50 minutes so treatment can be targeted from the first consultation.

40–50 minTime to result
>90% / >95%Sensitivity / specificity
mecATarget gene for methicillin resistance (MRSP / MRSA)
Heat blockThe only equipment needed, available from WeDetect

Why methicillin resistance matters

Methicillin-resistant staphylococci, especially methicillin-resistant Staphylococcus pseudintermedius (MRSP) in dogs, are an established concern in small animal practice. The mecA gene makes these bacteria resistant to most beta-lactam antibiotics, including the penicillins and cephalosporins often chosen first.

If MRSP or MRSA causes a skin, ear, wound or urinary tract infection, first-line treatment is likely to fail. Culture results usually take several days, so treatment is often started before resistance is known.

How the test supports your decision

  • Avoid ineffective first-line treatment: know whether beta-lactams are an option at the first visit
  • Support responsible antimicrobial use: base the choice of antibiotic on evidence rather than assumption
  • Act on infection control early: identify resistant infections so hygiene measures can start straight away
  • Explain the treatment plan clearly: discuss results with the owner during the same visit

How it works

The test uses loop-mediated isothermal amplification (LAMP), a molecular method that runs at one constant temperature. No thermal cycler or laboratory is needed.

1

Collect the sample

Swab the lesion or ear, or use a urine sample or bacterial colony, as described in the instructions for use.

2

Run the test

Add the prepared sample to the test vessel and place it in the WeDetect heat block.

3

Read the result

After 40–50 minutes, read a positive or negative result for mecA.

What you need

WeDetect Methicillin Resistance Test

  • 5 tests per pack
  • 12-month shelf life
  • For veterinary use only

WeDetect heat block

  • Available from WeDetect at low cost
  • The only equipment needed to run the test
  • No thermal cycler or laboratory required

Ask about the heat block when you request a quote for tests.

Specifications

ParameterValue
TargetmecA (mecC is not covered)
OrganismsStaphylococcus pseudintermedius, S. aureus, other coagulase-positive staphylococci
SpeciesDogs and cats
Sample typeSkin/wound swab, ear swab, urine, bacterial colony
MethodLAMP (loop-mediated isothermal amplification)
Time to result40–50 minutes
SensitivityAbove 90%
SpecificityAbove 95%
EquipmentWeDetect heat block (available from WeDetect at low cost)
Pack size5 tests per pack
Shelf life12 months (storage: 2–8 °C)
Intended useFor veterinary use only

The test detects a genetic resistance marker. Results should be read together with the clinical picture. Culture and susceptibility testing remain recommended for serious or recurrent infections.

Frequently asked questions

Which patients should be tested?

Patients with recurrent or non-responding pyoderma, otitis, wound or surgical site infections, and animals with previous antibiotic treatment, hospital stays or known contact with MRSP or MRSA.

What does a positive result mean?

The mecA gene was detected. Treat the staphylococcal infection as methicillin-resistant: beta-lactam antibiotics such as penicillins, amoxicillin-clavulanate and cephalosporins should not be expected to work. Culture and susceptibility testing can guide the choice among the remaining options.

Does a negative result rule out resistance?

A negative result means mecA was not detected in the sample. The test does not detect mecC or resistance to other antibiotic classes, and results should always be read together with the clinical picture.

What equipment do I need?

Only the WeDetect heat block, which WeDetect supplies at low cost. No thermal cycler or laboratory equipment is needed.

Can it be combined with other WeDetect tests?

Yes. Clindamycin is often considered when a staphylococcus is methicillin-resistant, so the test pairs well with the WeDetect Clindamycin Resistance Test.

Bring rapid resistance testing into your clinic

Contact us for pricing on tests and the WeDetect heat block.